FOB Fecal Occult Blood uncut sheet

Short Description:

Fecal Occult Bllod FOB uncut sheet

Methodology: Colloidal Gold


  • Testing time: 15 minutes
  • Storage temperature: 2°C-30°C
  • Valid Time: 24 months
  • Accurancy: More than 99%
  • Specification: 25 test/box
  • Product Detail

    Product Tags

    1. INTEDED USE

    This kit is used for qualitative detection of hemoglobin in human stool sample and is used for evaluating of gastrointestinal bleeding. The kit only provides the test result of f hemoglobin, and the obtained result shall be analyzed in combination with other clinical information.

     

    2. PRODUCT SPECIFICATION

    Model No. FOB Uncut sheet
    Methodology Colloidal Gold
    Sample Type Faces 
    Time to Result 10-15mins
    Storage 2~30 ℃/36~86℉
    Shelf Life 24 months
    Certificate ISO13485, CE Certificate, UCKA MHRA Certificate
    uncut sheet
    uncut sheet

    Feature

      High sensitive

    •  result reading in 15-20 minutes

    •  Easy operation

    •  High Accuracy

    PACKING

    * 20 bags /CTN

    * Aluminum foil bag labeling

    * shrink wrap

     

    3.TEST METHOD

    1 Use sample collection tube to collect, mix well and dilute the sample. Use sampling stick to take about 30mg of stool. Then, transfer the stool to a sample collection tube containing sample diluent, tighten by rotating, and shake sufficiently.
    2 If stool of patient with diarrhea is loose, use disposable pipette to draw the sample, add 3 drops (about 100μL) of sample-to-sample collection tube, and shake the sample and sample diluent sufficiently.
    3 Take the test device out of the aluminum foil bag, place it on a horizontal worktable flat, and make a proper mark.
    4 Discard the first two drops of diluted sample. Then, vertically, and slowly add 3 drops (about 100μL) of bubble-Free diluted sample to the center of sample hole of the test device and start timing.
    5 The result shall be read within 10-15 minutes. Test result obtained after 15 minutes is invalid (for detail about result see Interpretation of Test Results).

     

    4.RESULT EVALUATION AND EXPLANATION

    微信图片_20241028154133

    5.CLINICAL PERFORMANCE

    Clinical performance of this product’s assessed through collection of 288 cases of clinical samples. Sample providers include patients with abnormal calprotectin index, patients with fecal occult blood and normal people. Marketed kit of colloidal gold methods used as reference reagent. The WIZ BIOTECH reagent test will be compared with the control reagent:

    Baysen Result of FOB
    Test result of Reference reagent Positive coincidence rate:
    99.33(95%C.I.96.32%~99.88%)
    Negative coincidence rate:
    100.00(95%C.I.97.29%~100.00%)
    Total coincidence rate:99.65% (95%C.I. 98.06%~99.94%)
    Positive  Negative  Total
    Positive 149 0 149
    Negative  1 138 139
    Total 150 138 288

    6. CERTIFICATE

    * ISO System Certificate

    * CE Certificate

    * EU Registration

    * UCKA MHRA Registration


  • Previous: